精品国产美女在线一区二区三区_午夜亚洲?v日韩?v无码大全_中文字幕制服丝袜在线观看_人妻91无码久久一二三区免费_亚洲日韩精品无码专区97_亚洲午夜av免费_国产高清在线视频伊甸园_日韩成人免费体验_欧美日韩色精品人妻在线视频_亚洲无线观看国产色多多下载

PT500-801S
    Model: PT500-801S
    Imported differential pressure chip, the maximum range of differential pressure is 25MPa, the maximum static pressure is 70MPa;
    304 shell material, suitable for measuring liquid, gas and other media differential pressure;
    Four digit display header, one decimal place;
    Sampling rate of meter head: 10 times / S;
    4-20mA two-wire current output;
    T-shaped structure, easy to install, m20x1.5/g1/2 process connection;

    Common keywords:
    Digital differential pressure transmitter digital differential pressure sensor
    Digital differential pressure transmitter digital differential pressure sensor
    Digital differential pressure sensor digital differential pressure transmitter
    Product description of strain type pressure transmitter:
    Model: PT500-801S
    Imported differential pressure chip, the maximum range of differential pressure is 25MPa, the maximum static pressure is 70MPa;
    304 shell material, suitable for measuring liquid, gas and other media differential pressure;
    Four digit display header, one decimal place;
    Sampling rate of meter head: 10 times / S;
    4-20mA two-wire current output;
    T-shaped structure, easy to install, m20x1.5/g1/2 process connection;

    Common keywords:
    Digital differential pressure transmitter digital differential pressure sensor
    Digital differential pressure transmitter digital differential pressure sensor

    Digital differential pressure sensor digital differential pressure transmitter


    Chip:

    Imported differential pressure chip, the maximum differential pressure range is 25MPa;

    The maximum static pressure is 70MPa;

    3-5 times withstand voltage, suitable for measuring differential pressure of liquid, gas and other media;

    Zero, full, temperature compensation, linear compensation;

    High impedance, high precision and high stability;

    More than 1 million times of service life;


    Signal processing and output:
    24 bit ADC sampling and processing chip;
    DSP digital signal conditioning algorithm;
    Multipoint linear temperature calibration;
    Voltage and current overload protection;
    Standard industrial signal output: 4-20mA (two-wire system), 0-20mA (three wire system), 0-5vdc, 0-10vdc, 0.5-4.5vdc (three wire system);

    Digital communication signal output: rs485-rtu, ultra-low power rs485-rtu
    Advanced 32 bit microprocessor and 24 bit ADC are adopted
    The transmission protocol is MODBUS-RTU
    Support baud rate: 1200 ~ 57600bps, check bits: none, odd, even
    Support the user's secondary calibration, reset, anti reset, restore factory operations
    Support 11 kinds of units switching, support floating point, integer, percentage, formatted output
    The acquisition interval of 0 ~ 43200 seconds (12 hours) can be set, which can not only meet the needs of high-speed acquisition, but also trigger acquisition once to minimize power consumption

    Digital communication signal output: CAN2.0B
    Measurement rate: 10... 1000Hz can be set, the default is 50 Hz

    CANopen output built-in complete CANopen protocol stack, in line with ds301, ds404 specifications, support LSS services, support bootloader online upgrade;
    Support baud rate (kbps) 20 / 50 / 100 / 125 / 250 (default) / 500 / 800 / 1000; support features of NMT / heartbeat / SDO / PDO / LSS / bootloader; CANopen protocol stack can be customized according to user requirements;

    J1939 output has built-in J1939 protocol stack. PGN, SPN and name can be configured freely, and bootloader online upgrade is supported;
    Support baud rate (kbps) 20 / 50 / 100 / 125 / 250 (default) / 500 / 800 / 1000; support free configuration of features such as PGN, SPN and name
    The J1939 protocol stack can be customized according to the user's requirements;

    Structure:
    T-shaped structure, easy to install, m20x1.5/g1/2 process connection;
    Small structure, standard din43650 (hesman) electrical connection line;
    Supporting four / five core shielded cable;

    Application:
    Differential pressure measurement and monitoring of liquid, gas and other media;
    Differential pressure measurement and monitoring of urban pipe network and equipment hydraulic system;
    Differential pressure measurement and monitoring before and after filter screen, filter, etc;

    Application fields:
    • Oil pressure system

    • petrochemical industry

    • Petroleum Pipeline

    • Constant pressure water supply

    Specification parameter

    Measuring medium: liquid, gas and steam
    Pressure type: differential pressure
    Range:
    0~100、200、300、500、600(KPa);
    0~1、2、3、5、10、20(MPa);
    -100KPa~-10KPa~0~100(KPa);
    ±10KPa~±100KPa;
    Static pressure (pressure): 3 times of the range
    Comprehensive accuracy: ±0.25% FS; ±0.5% FS; ±1% FS
    Nonlinear: ≤0.5% FS
    Repeatability: ≤0.25% FS
    Output signal:
    Current mode: 4 ~ 20mA two wire system; 4 ~ 20mA / 0-20mA three wire system
    Four digit display, display range: - 1999 - 9999
    Sampling rate of pressure gauge: 10 times / S
    Supply voltage:24VDC(9~30VDC)
    Service life: ≥ 1million times
    Insulation impedance: ≥ 1000 m Ω/100VDC
    Load impedance: current output: ≤ 800 Ω; voltage output:≥50KΩ
    Medium temperature: -20~70 ℃/
    Ambient temperature: -20~70 ℃
    Compensation temperature: 0~60 ℃
    Response time: ≤3MS
    Overload pressure: 150% FS
    Failure pressure: 3 times of range (range less than 100KPA); 2 times of range (range more than 100KPA)
    Electrical connection: Standard din43650 (hesman) electrical connection outgoing line
    Protection grade: IP65 / IP68
    Connecting cable: four core shielded cable, standard length: 3M
    Connection material: 304/316
    Process connection: m20x1.5 (general), G1/2, etc Specification can be made by users







    Ordering considerations

    Precautions for ordering PT500-801S products
    1. Product range selection:
    In order to achieve the best effect of product precision, life, stability and other functions, the range selection of the product is calculated according to the following formula:
    Range = x (1.2-1.5) times of the maximum system pressure;
    The actual measuring pressure range of the product should be 15% - 80% of the measuring range;
    The static pressure (withstand voltage) is 3 to 5 times of the range value, that is, the maximum pressure value at the high pressure end;

    2. Product power supply and output:
    The selection of power supply range is determined according to the output specifications of the product:
    Conventional 4-20mA / 0-20mA, 0-5V / 10V output, DC 12-30vdc power supply;
    General rs485-rtu output, DC 12-30vdc power supply;
    0.5-4.5vdc output, DC 5VDC;

    3. The user should understand the measurement medium characteristics of the product:
    Medium specification, medium temperature, medium purity (whether containing impurities or particles, etc.);

    4. Users should understand the installation environment and installation method of the product:
    Indoor or outdoor installation;
    Ambient temperature;
    Required sealing level;
    Vibration range of equipment;
    Installation method: thread, flange, special structure;
    Whether the installation space meets the overall dimension of the product;
    Precautions for use

    It is strictly forbidden that the power supply scope of the product exceeds the specified standard of the product;

    The measuring medium of the product is suitable for measuring gas, liquid, steam, etc;

    It is strictly forbidden to use hard objects (such as screwdrivers, fingers, iron nails, etc.) to make the pressure diaphragm output by pressure measurement;

    The power and signal wires should be correctly connected according to the specifications of the ordered products;

    It is strictly forbidden that the medium temperature, pressure range and excitation voltage of the measured system exceed the rated range of the transmitter;

    Attention should be paid to the protection of the outgoing cable of the transmitter. When the field use span is too large, it is recommended to use metal tube protection or overhead;

    Pressure transmitter is a precision measuring instrument, do not force impact, fall, so as not to damage the core

    The product is installed in a ventilated, dry and non corrosive environment, with protective devices installed in the open air to avoid direct sunlight;

    It is strictly forbidden to enter water / leak water / soak water in the product instrument, and it should be installed in the open air with protective device to avoid direct sunlight;

    Common problem
    Proposal
    Name
    Tel
    QQ
    WeChat
    Mailbox
    Address
    Content
    Foshan puliang Electronic Co., Ltd

    Tel:0757-26619568 Fax: 0757-26619508

    24-hour online technical support:13790092618

    Cloud platform:www.puliangiot.com

    Address:501, block 8, phase 5, Rongli tianfulai industrial city, Ronggui town, Shunde District, Foshan City

    Copyright©Foshan puliang Electronic Co., Ltd