PT500-706P
Steam supply system
Oil pressure system
Metallurgical equipment
petrochemical industry
Measuring medium: liquid, gas, steam, etc
Pressure form: gauge pressure, absolute pressure
Range:
0~0.6、1、2、5、10、15、20、25、30、40、50、60(MPa);
0~100、150、200(MPa);
-100KPa-0.6~10MPa;
Comprehensive accuracy: ± 0.25% FS; ± 0.5% FS; ± 1% FS
Nonlinearity: ≤ 0.25% FS
Repeatability: ≤ 0.15% FS
Pressure output signal:
Current type: 4-20mA two-wire system; 4-20mA / 0-20mA three-wire system
Voltage type: 0 ~ 5VDC, 0 ~ 10VDC, 0.5 ~ 4.5vdc three wire system
Digital type: rs485-rtu, low power rs485-rtu
CAN2.0B (supports CANopen, J1939 Protocol)
Temperature output signal: PT100 resistance signal
Supply voltage:
24 VDC (9 ~ 30 VDC) universal type
3.1 ~ 6.1vdc (low power rs485-rtu)
5VDC (0.5 ~ 4.5vdc output type)
Service life: ≥ 1 million times
Insulation impedance: ≥ 1000 m Ω / 100VDC
Load impedance: current output: ≤ 800 Ω; voltage output: ≥ 50K Ω
Medium temperature: - 20 ~ 80 ℃
Ambient temperature: - 20 ~ 70 ℃
Compensation temperature: 0 ~ 70 ℃
Response time: ≤ 5ms
Overload pressure: 150% FS
Failure pressure: 3 times of measuring range (less than 40MPa); 2 times of measuring range (measuring range greater than 41mpa)
Electrical connection: four core hesman connector (din43650) or waterproof tight wire nut directly lead out;
Protection grade: IP67 / IP68
Connecting cable: Four / five / six core shielded cable, standard length: 3M
Connection material: 304 / 316L
Tel:0757-26619568 Fax: 0757-26619508
24-hour online technical support:13790092618
Cloud platform:www.puliangiot.com
Address:501, block 8, phase 5, Rongli tianfulai industrial city, Ronggui town, Shunde District, Foshan City