Chip:
Adopt imported pressure sensitive chip; select the chip technology;Oil pressure system
Metallurgical equipment
Gas supply system
Gas supply pipeline
1、 Technical parameters
Measuring medium: liquid and gas (compatible with connecting materials of product process)
Pressure form: gauge pressure, absolute pressure
Range: 0 ~ 0.6 ~ 60MPa; - 0.1 ~ 0 ~ 0.6 ~ 5MPa
Comprehensive accuracy: ± 0.25% FS; ± 0.5% FS; ± 1% FS
Non linear: ≤ 0.25% FS
Repeatability: ≤ 0.1% FS
Output signal: 1.0 ± 0.5mv/v (four wire system / six wire system) differential bridge output
Power supply voltage: constant voltage: 5VDC (3-10vdc)
Insulation impedance: ≥ 1000m Ω / 100VDC
Output impedance: range 0-20mpa: 2000 Ω; range 21-60mpa: 1650 Ω
Medium temperature: - 20-80 ℃
Ambient temperature: - 20 ~ 70 ℃
Compensation temperature: 0 ~ 70 ℃
Response time: ≤ 5ms
Overload pressure: 150% FS
Failure pressure: 5 times of range (range less than 5MPa); 3 times of range (range greater than 5MPa)
Electrical connections: direct leads
Protection grade: IP65
Connecting cable: four core color cable, standard length: 50mm
Connection material: 304 / 316L
Process connection: m20x1.5, G1 / 2, G1 / 4, ZG1 / 4, 1 / 4NPT, ZG1 / 2, G3 / 8, m12x1.5
2、 Specification and model
5、 Installation method
1. Product range selection:
In order to achieve the best effect of product accuracy,
life, stability and other functions, the range selection of the product is
calculated by referring to the following formula:
Range = x (1.2-1.5) times of the maximum system
pressure;
The actual measuring pressure range of the product
should be 15% - 80% of the range;
2. Product power supply and output:
The power supply of pressure core is constant voltage
source (3-10vdc);
The core output is differential bridge output;
The output signal is about (0.6-1.5) MV / V
3. The user should understand the measurement medium characteristics
of the product:
Medium specification, medium temperature, medium
purity (whether containing impurities or particles, etc.);
4. Users should understand the installation
environment and installation method of the product:
Indoor or outdoor installation;
Ambient temperature;
Required sealing level;
Vibration range of equipment;
Installation method: thread, flange, special
structure;
Whether the installation space meets the overall
dimension of the product;