精品国产美女在线一区二区三区_午夜亚洲?v日韩?v无码大全_中文字幕制服丝袜在线观看_人妻91无码久久一二三区免费_亚洲日韩精品无码专区97_亚洲午夜av免费_国产高清在线视频伊甸园_日韩成人免费体验_欧美日韩色精品人妻在线视频_亚洲无线观看国产色多多下载

PT100-T1 Temperature sensor
    Imported PT100 platinum resistor / J, K and e thermocouple temperature core is adopted;
    The selected patch process has zero point, full scale and temperature compensation;
    Accuracy grade: Grade B, Grade A and grade 1 / 3b are optional;
    The product has fast response, sensitive response and high precision;
    Product description of strain type pressure transmitter:

    PT100-T1 Temperature sensor


    Model: PT100-T1 temperature sensor
    Imported PT100 platinum resistor / J, K and e thermocouple temperature core is adopted;
    The selected patch process has zero point, full scale and temperature compensation;
    Accuracy grade: Grade B, Grade A and grade 1 / 3b are optional;
    The product has fast response, sensitive response and high precision;
    Diversified structure: thread installation type, armored type, patch type, plug-in type, flange type, etc;
    Air connection IP65 / 68, two wire / three core / four core shielded temperature compensation wire;
    304 / 316 / corundum tube / alloy and other shell materials;
    Temperature range: - 198 ℃ ~ - 40 ℃ ~ 0 ~ 100 ℃ ~ 500 ℃ ~ 1000 ℃;
    Probe rod length / diameter / thread specification / flange size can be formulated;
    It can replace foreign high-voltage products of the same type;
    PT100-T1 temperature sensor Main applications:
    Temperature measurement and monitoring of inner cavity of pipeline / equipment;
    Equipment temperature monitoring;
    Temperature measurement and control in automation / Agriculture / chemical industry / electric power / meteorology and other fields


    Application fields:
    • Intelligent fire control

    • Steam supply system

    • Metallurgical equipment

    • petrochemical industry

    Specification parameter

    PT100-T1 Temperature sensor


    Measuring medium: liquid and gas (compatible with product process connecting materials)
    Pressure form: gauge pressure and absolute pressure
    Range:
    -50 ℃ ~ 100 ℃ / mainly measuring ambient temperature;
    0 ℃ ~ 100 ℃ ~ 500 ℃ / PT100 type measures the temperature of high-temperature medium;
    0 ℃ ~ 500 ℃ ~ 1000 ℃ / thermocouple type to measure the temperature of high temperature / ultra-high temperature medium;
    Comprehensive accuracy:
    PT100 type: Class A, class B, class 1 / 3B
    Thermocouple type: class I, II and III
    Output signal:
    PT100 type: resistance signal (refer to the graduation table)
    PT1000 type: resistance signal (refer to the graduation table)
    Thermocouple type: MV voltage signal (refer to the graduation table)
    Insulation impedance: ≥ 1000 m Ω / 100VDC
    Medium temperature:
    -50 ℃ ~ 100 ℃ / mainly measuring ambient temperature;
    0 ℃ ~ 100 ℃ ~ 500 ℃ / PT100 type measures the temperature of high-temperature medium;
    0 ℃ ~ 500 ℃ ~ 1000 ℃ / thermocouple type to measure the temperature of high temperature / ultra-high temperature medium;
    Ambient temperature: - 40 ~ 70 ℃
    Stability: ≤± 0.5% FS / year
    Vibration influence: ≤± 0.25% FS / year (mechanical vibration frequency 20Hz ~ 1000Hz)
    Withstand pressure: less than 10 atmospheres in general, customized for special requirements
    Protection grade: IP65 / IP68
    Connecting material: 304 / 316L / corundum, etc
    Process connection: m20x1 5. G1 / 2, specifications formulated by users




    Ordering considerations
    Precautions for ordering PT100-T1 temperature sensor

    1. Product range selection:
    In order to achieve the best effect of product accuracy, service life, stability and other functions, the range of the product is calculated according to the following formula:
    Range = x (1.2-1.5) times the maximum temperature of the system;
    The actual measuring pressure range of the product should be 15% - 80% of the measuring range;

    2. Product output / accuracy level / acquisition method:
    Different product specifications and accuracy levels:
    PT100 type: Class A, class B, class 1 / 3B
    Thermocouple type: class I, II and III
    The back-end acquisition mode of the temperature sensor shall match the output of the sensor
    PT100 type: resistance signal. The resistance signal of Pt100 can be collected as required by the acquisition instrument or input module or board;
    PT1000 type: resistance signal. The resistance signal of PT1000 can be collected as required by the acquisition instrument or input module or board;
    Thermocouple type: MV voltage signal. The signal of thermocouple can be collected as required by the acquisition instrument or input module or board;

    3. Users need to understand the characteristics of the measuring medium of the product:
    Medium specification, medium temperature, medium purity (whether it contains impurities or particles, etc.);

    4. Users should understand the installation environment and installation method of the product:
    Indoor or outdoor installation;
    Ambient temperature;
    Sealing grade requirements;
    Vibration range of equipment;
    Pressure seal mode: taper seal, end face seal, arc seal and spherical seal;
    Whether the installation space meets the overall dimension of the product;

    Precautions for use
    Precautions for use of Pt100-T1 temperature sensor

    For installation and use, please check whether the relevant parameters of the product label and certificate are consistent with the operating conditions;
    When the thermal resistance / thermocouple is installed, its insertion depth shall not be less than 8 ~ 10 times of the outer diameter of the thermal resistance protection tube;
    Increase the heating part of thermal resistance / thermocouple as much as possible;
    The thermal resistance / thermocouple shall be installed vertically as far as possible to prevent bending and deformation at high temperature.
    In order to reduce the error during the use of thermal resistance / thermocouple, the surface of protective sleeve shall be close to the temperature of measured medium as much as possible;
    When installing the product, the stressed part is "process connection hexagonal wrench position", and the wrench specification corresponds to the hexagonal wrench position;
    It is strictly prohibited that the medium temperature, pressure range and excitation voltage of the measured system exceed the rated service range of the transmitter;
    Pay attention to protect the sensor / transmitter cable or compensation wire;
    Try to avoid direct access to user devices or electrical appliances causing interference;
    Common problem
    Proposal
    Name
    Tel
    QQ
    WeChat
    Mailbox
    Address
    Content
    Foshan puliang Electronic Co., Ltd

    Tel:0757-26619568 Fax: 0757-26619508

    24-hour online technical support:13790092618

    Cloud platform:www.puliangiot.com

    Address:501, block 8, phase 5, Rongli tianfulai industrial city, Ronggui town, Shunde District, Foshan City

    Copyright©Foshan puliang Electronic Co., Ltd