精品国产美女在线一区二区三区_午夜亚洲?v日韩?v无码大全_中文字幕制服丝袜在线观看_人妻91无码久久一二三区免费_亚洲日韩精品无码专区97_亚洲午夜av免费_国产高清在线视频伊甸园_日韩成人免费体验_欧美日韩色精品人妻在线视频_亚洲无线观看国产色多多下载

Temperature and humidity transmitter PTH100
    Imported PT100 platinum resistance+humidity sensor digital chip;
    Product structure: armored;
    High precision, stable, digital calibration and adjustment, amplification IC;
    Fast response, sensitive response, high precision and long-term stability;
    Temperature and humidity respectively output 4-20mA analog signals;
    Diversified structure: thread mounted, armored, plug-in, flange, etc;
    Gas connection IP65/68;
    Product description of strain type pressure transmitter:

    PTH100 temperature and humidity integrated transmitter Pipeline temperature and humidity transmitter


    PTH100 temperature and humidity integrated transmitter Characteristics of pipeline temperature and humidity transmitter

    Imported PT100 platinum resistance+humidity sensor digital chip;

    Product structure: armored;

    High precision, stable, digital calibration and adjustment, amplification IC;

    Fast response, sensitive response, high precision and long-term stability;

    Temperature and humidity respectively output 4-20mA analog signals;

    Diversified structure: thread mounted, armored, plug-in, flange, etc;

    Gas connection IP65/68;

    304/316 and other material shells;

    Operating temperature range: - 0~+50 ℃, - 20~80 ℃, - 40~60 ℃, - 40~120 ℃ (optional);

    Operating humidity range: 0-99.9% RH;

    The length/diameter/thread specification/flange size of the probe can be determined;

    It can replace the same type of foreign high-voltage products;

    PTH100 temperature and humidity integrated transmitter is mainly used for:

    Monitoring the temperature and humidity of textile, food, scientific research, environmental protection and warehouse environment;

    Monitoring the ambient temperature and humidity of meteorological stations (stations), workshops, workshops and warehouses;

    Monitoring of temperature and humidity in libraries, offices, computer rooms, laboratories and greenhouses;


    Application fields:
    • Central air conditioning unit

    • Intelligent fire control

    • Smart city

    • Fire fighting system

    Specification parameter

    PTH100 temperature and humidity integrated transmitter Pipeline temperature and humidity transmitter

    Main technical parameters and specifications:
    Temperature range: - 0~+50 ℃- 20~+80℃;- 40~+60℃;- 40~+120℃
    Humidity range: 0 ~ 99.9% RH
    Temperature accuracy: ± 0.5% FS; ±1%FS; ±2%FS; (25℃)
    Humidity accuracy: ± 3% RH (25 ℃)
    Output signal: current type: 4-20mA (three wire system), temperature and humidity output respectively;
    Power supply voltage: 24VDC (15-30VDC);
    Insulation impedance: ≥ 1000 M Ω/100VDC;
    Ambient temperature: - 40~70 ℃
    Power on time: 3S
    Product power consumption:<0.05W
    Resolution: temperature: 0.1 ℃; Humidity: 0.1% RH
    Sensitivity attenuation value: temperature<0.1 ℃; Humidity<0.5% RH
    Protection grade: IP65/IP68
    Connection material: 304/316L, etc
    Process connection: M20X1.5, G1/2, user made specifications



    PTH100溫濕度一體變送器結(jié)構(gòu)尺寸:

    PTH100溫濕度一體變送器接線方式:


    PTH100溫濕度一體變送器安裝方式
    Ordering considerations
    Precautions for use
    For installation and use, check whether the relevant parameters of the product label and certificate are consistent with the operating conditions;

    When installing the thermal resistance/thermocouple, its insertion depth shall not be less than 8~10 times of the outer diameter of the thermal resistance protection tube;

    Increase the heating part of thermal resistance/thermocouple as much as possible;

    It is prohibited to stay in the steam, water mist, water curtain or condensation environment for a long time;

    In the dust or other polluted environment, the products must be cleaned regularly;

    Thermal resistance/thermocouple shall be installed vertically as far as possible to prevent bending deformation under high temperature.

    In order to reduce the error during the use of thermal resistance/thermocouple, try to make the surface of protective sleeve close to the temperature of measured medium;

    During product installation, the stressed part is "process connection hexagonal wrench position", and the wrench specification corresponds to the hexagonal wrench;

    It is strictly forbidden that the medium temperature, pressure range and excitation voltage of the measured system exceed the rated range of the transmitter;

    Protect the sensor/transmitter cable or compensation wire;

    Try to avoid directly approaching user devices or electrical appliances that cause interference;
    Common problem
    Proposal
    Name
    Tel
    QQ
    WeChat
    Mailbox
    Address
    Content
    Foshan puliang Electronic Co., Ltd

    Tel:0757-26619568 Fax: 0757-26619508

    24-hour online technical support:13790092618

    Cloud platform:www.puliangiot.com

    Address:501, block 8, phase 5, Rongli tianfulai industrial city, Ronggui town, Shunde District, Foshan City

    Copyright©Foshan puliang Electronic Co., Ltd