精品国产美女在线一区二区三区_午夜亚洲?v日韩?v无码大全_中文字幕制服丝袜在线观看_人妻91无码久久一二三区免费_亚洲日韩精品无码专区97_亚洲午夜av免费_国产高清在线视频伊甸园_日韩成人免费体验_欧美日韩色精品人妻在线视频_亚洲无线观看国产色多多下载

Welcome to the website of Foshan puliang Electronic Co., Ltd Mobile           中文   EN
Hot Keywords:Pressuresensor Pressure transmitter level sensor Temperature sensor
PT500-503S
Model: pt500-503s
Main features:
Adopt imported voltage sensing chip; select the chip technology, with zero, full range compensation, temperature compensation;
High precision stable amplifier IC;
Industrial standard analog quantity 4-20mA output;
Four LED display integrated instrument, on-site real-time display of pressure value;
Common keywords:
Digital pressure transmitter digital pressure sensor
Digital pressure transmitter digital pressure sensor
With display pressure sensor with display pressure transmitter
<
>
  • Product parameters
  • Specification parameter
  • Ordering considerations
  • Precautions for use
  • Common problem
  • Proposal

Chip:
Imported brand pressure sensitive chip wafer;
Selected chip technology and fully sealed package;

Core:
Diffused silicon core, high sensitivity, large output, zero point, full range compensation, temperature compensation, suitable for small range pressure transmitter;
Strain gauge core, high-strength elastic deformation pressure sensing material, equipped with temperature compensation, has the advantages of impact resistance and fatigue resistance, suitable for general range pressure transmitter;
Ceramic core, outstanding anti-corrosion performance, with zero point, full range compensation, temperature compensation; suitable for measuring medium with strong corrosive working conditions, range less than 5MPa;

Structure:
Small overall structure, diversified process connection modes (thread M20, M16, M12, G1 / 4, G1 / 2, 1 / 2NPT, 1 / 4NPT, flange connection, quick joint, welding, etc.)
Standard electrical connection interface: Hersman din34650
Process connection material: 304 or 316;
Shell material: 304 or 316;
Standard four core shielded cable for pressure measurement

Signal processing:
24 bit ADC sampling processing chip;
DSP digital signal conditioning algorithm;
Multipoint line temperature calibration;
Voltage and current overload protection;
Standard industrial signal output: 4-20mA (two-wire system);
Four LED display integrated instrument, on-site real-time display pressure value, display range: - 1999 - 9999;

Application fields:
  • Intelligent fire control

  • Smart city

  • Oil pressure system

  • Air supply system

  • Petroleum Pipeline

  • Constant pressure water supply

1、 Technical parameters

Measurement medium: liquid and gas (compatible with product process connection materials)

Pressure form gauge pressure, absolute pressure

Range: 0-0.6-60mpa

-0.1~0~0.6~5MPa

-100KPa~10KPa~40MPa

±10KPa~±100KPa

Comprehensive accuracy ± 0.25% FS; ± 0.5% FS; ± 1% FS

Nonlinear ≤ 0.25% FS

Repeatability ≤ 0.1% FS

Output signal 4-20mA (two-wire system)

Display instrument: four digit display, display range: - 1999 - 9999

Power supply voltage: 24VDC (9-30vdc)

Insulation impedance ≥ 1000m Ω / 100VDC

Load impedance current output: ≤ 800 Ω; voltage output: ≥ 50K Ω

Medium temperature - 20-80 ℃

Ambient temperature - 20-70 ℃

Compensation temperature 0-70 ℃

Response time ≤ 5ms

Overload pressure 150% FS

5 times of range (range less than 5MPa); 3 times of range (range greater than 5MPa)

Electrical connection Hersman (din34650)

IP 65

Connecting cable: four core shielded cable, standard length: 3M

Connection material 304 / 316L

Process connection m20x1.5, G1 / 2, G1 / 4, ZG1 / 4, 1 / 4NPT, ZG1 / 2, G3 / 8, m12x1.5

2、 Specification and model

3、 Structural dimensions

4、 Electrical connection

5、 Installation method


1. Product range selection:

In order to achieve the best effect of product accuracy, life, stability and other functions, the range selection of the product is calculated by referring to the following formula:

Range = x (1.2-1.5) times of the maximum system pressure;

The actual measuring pressure range of the product should be 15% - 80% of the range;

2. Signal output mode of the product:

The signal output specification depends on the requirements of the back-end acquisition equipment;

Common are: control and display instrument, PLC acquisition and input module, MCU acquisition card, PC serial port, etc

If the back-end acquisition equipment is determined according to the output specification of the product, it is recommended to use the general two-wire system 4-20mA;

3. The user should understand the measurement medium characteristics of the product:

Medium specification, medium temperature, medium purity (whether containing impurities or particles, etc.);

4. Users should understand the installation environment and installation method of the product:

Indoor or outdoor installation;

Ambient temperature;

Required sealing level;

Vibration range of equipment;

Installation method: thread, flange, special structure;

Whether the installation space meets the overall dimension of the product;

5. Whether the display resolution of the product meets the use requirements of the equipment;

Display range of display instrument: - 1999 – 9999, with variable decimal point;

6. The output signal of the product instrument display is only one of 4-20mma two-wire system, without signal output of other specifications (such as voltage 0-5vdc or 0-10vdc output);


Product power supply 24VDC (range: 9-30vdc);

It is strictly prohibited to use hard objects (such as screwdriver, finger, iron nail, etc.) to make the pressure core body under pressure measurement output;

The power and signal wires shall be correctly wired according to the specifications of the ordered products;

When the product is installed, the stressed part is "process connection hexagon wrench position", and the wrench specification corresponds to hexagon;

It is strictly prohibited that the medium temperature, pressure range and excitation voltage of the tested system exceed the rated use range of the transmitter;

Pay attention to protect the outgoing cable of the transmitter. When the span is too large on site, it is recommended to use metal pipe for protection or overhead;

The pressure transmitter is a precision measuring instrument. Do not impose impact or smash to avoid damaging the core

The product is installed in a ventilated, dry and non corrosive environment, and installed in the open with protective devices to avoid direct sunlight;

No water or water leakage is allowed for the product instrument, and protective devices shall be installed in the open air to avoid direct sunlight;

Question 1: no output from pressure transmitter?

Reverse connection of power line: wiring according to the requirements of product instruction / product certificate / product label

Poor wiring of electrical connector: disassemble the electrical connector and check whether the wiring of each terminal pin is firm;

Cable open circuit: replace cable

Transmitter amplifier board burnt out: repair or replacement;

Question 2: pressure transmitter output 3.92ma?

The power supply voltage is less than the required value: the normal minimum power supply voltage is 9VDC, check the voltage value

Insufficient power of power supply: whether the power of power supply meets the requirements of rated load;

Excessive load of acquisition circuit: check the circuit load

Pressure value exceeds the minimum range value: whether negative pressure is formed at the pressure tap of the transmitter;

Pressure transmitter amplifier board burned out: repair or replacement

Impact or overpressure core damage: repair or replace;

Question 3: pressure transmitter output 22mA?

The power supply voltage is less than the required value: the normal minimum power supply voltage is 9VDC, check the voltage value

Insufficient power of power supply: whether the power of power supply meets the requirements of rated load;

Pressure value exceeds the maximum range value: check the loading pressure of pressure transmitter;

Pressure transmitter amplifier board burned out: repair or replacement

Impact or overpressure core damage: repair or replace;

Question 4: unstable pressure transmitter output?

Unstable pressure source: check whether the pressure of the pressurization system is stable;

No grounding wire: pressure transmitter and equipment are grounded

The installation position of the transmitter has a large magnetic field: install a shield or replace the installation position;

The cable is too long and passes through the magnetic field: replace the cable routing position;

Transmitter water or steam: put the transmitter into the temperature box when the transmitter is not powered on, and heat it to 65 for drying;

Stone sand or sundries in pressurized pipeline: cleaning;

Question 5: is there no display on the indicator head of the pressure transmitter, incomplete display characters, and character jumping?

No display with current output: LED or LCD display broken, repair or replace

Incomplete display characters: water, poor contact or faulty welding, repair or replacement;

Character runout: the vibration of the installation position exceeds the allowable range or the contact is poor, repair or replace;

Display garbled Code: program error or water inflow, etc., repair or replace

Question 6: the output of the pressure transmitter is abnormal after the load is connected?

Output current is very small at 0 pressure: input impedance of load exceeds 500 ohm;

The output current is very small when the pressure is 0: the power of the power supply does not meet the requirements of the sensor;

Output current exceeds 15mA at 0 pressure: power supply does not meet sensor requirements;

No output at 0 pressure: whether the power supply and signal are connected reversely, and there is no corresponding seat;
Name
Tel
QQ
WeChat
Mailbox
Address
Content