Model: PT500-706 It adopts precision stable pressure sensitive chip and selective placement technology; Integrated structure of temperature and pressure, monitoring pressure and temperature at the same time; Double measurement and double output; High precision, stable, digital calibration adjustment, amplification integrated circuit; It can replace foreign products of the same type;
Common keywords: Integrated temperature and pressure transmitter Integrated pressure and temperature transducer
Chip: It adopts precision stable pressure sensitive chip and selective placement technology; PT100 high precision temperature sensor; Zero point, fullness, temperature compensation and linear compensation; High impedance, high precision and high stability; More than 1 million times of service life;
Signal processing and output: 24 bit ADC sampling and processing chip; DSP digital signal conditioning algorithm; Multipoint linear temperature calibration; Voltage and current overload protection; Standard industrial signal output: 4-20mA (two-wire system), 0-20mA (three wire system), 0-5vdc, 0-10vdc, 0.5-4.5vdc (three wire system);
Rsu-485, ultra low power consumption of rtu-485 communication Advanced 32 bit microprocessor and 24 bit ADC are adopted The transmission protocol is MODBUS-RTU Support baud rate: 1200 ~ 57600bps, check bits: none, odd, even Support the user's secondary calibration, reset, anti reset, restore factory operations Support 11 kinds of units switching, support floating point, integer, percentage, formatted output The acquisition interval of 0 ~ 43200 seconds (12 hours) can be set, which can not only meet the needs of high-speed acquisition, but also trigger acquisition once to minimize power consumption Digital communication signal output: CAN2.0B Measurement rate: 10... 1000Hz can be set, the default is 50 Hz
CANopen output built-in complete CANopen protocol stack, in line with ds301, ds404 specifications, support LSS services, support bootloader online upgrade; Support baud rate (kbps) 20 / 50 / 100 / 125 / 250 (default) / 500 / 800 / 1000; support features of NMT / heartbeat / SDO / PDO / LSS / bootloader; CANopen protocol stack can be customized according to user requirements;
J1939 output has built-in J1939 protocol stack. PGN, SPN and name can be configured freely, and bootloader online upgrade is supported; Support baud rate (kbps) 20 / 50 / 100 / 125 / 250 (default) / 500 / 800 / 1000; support free configuration of features such as PGN, SPN and name The J1939 protocol stack can be customized according to the user's requirements;
Structure: Thick film structure: deep argon arc welding, connecting elastic material and process joint, high strength, impact resistance and fatigue resistance; PU film structure: laser welding, connecting elastic material and process joint, transmitting pressure with silicone oil medium, fast response, fatigue resistance, small range; Integrated structure of temperature and pressure, monitoring pressure and temperature at the same time; The overall structure is compact, and the process connection mode is diversified (m20x1.5, G1 / 2, ZG1 / 2, 1 / 2NPT (thread diameter ≥ 17mm) DN50, etc.); Process connection material: 304 or 316;
Application: Pressure measurement and monitoring of power station, oil plant, chemical industry, etc; Pressure measurement of equipment with flameproof requirements for products in automation and other fields;
Precautions for ordering PT500-706 products 1. Product range selection: In order to achieve the best effect of product accuracy, life, stability and other functions, the range selection of the product is calculated by referring to the following formula: Range = x (1.2-1.5) times of the maximum system pressure; The actual measuring pressure range of the product should be 15% - 80% of the range;
2. Product power supply and output: The selection of power supply range is determined according to the output specifications of the product: Conventional 4-20mA / 0-20mA, 0-5V / 10V output, DC 12-30vdc power supply; General rs485-rtu output, DC 12-30vdc power supply; 0.5-4.5vdc output, DC 5VDC; Low power output power supply range: 3.6vdc (3-5vdc)
3. The user should understand the measurement medium characteristics of the product: Medium specification, medium temperature, medium purity (whether containing impurities or particles, etc.);
4. Users should understand the installation environment and installation method of the product: Whether the flameproof protection level can meet the requirements of field conditions; Indoor or outdoor installation; Ambient temperature; Required sealing level; Vibration range of equipment; Installation method: thread, flange, special structure; Whether the installation space meets the overall dimension of the product;
Different product signal output specifications correspond to different power supply range requirements; It is strictly prohibited to use hard objects (such as screwdriver, finger, iron nail, etc.) to make the pressure diaphragm output under pressure measurement; The power and signal wires shall be correctly wired according to the specifications of the ordered products; During product installation, the stressed part is "process connection hexagon wrench position", and the wrench specification corresponds to hexagon; It is strictly prohibited that the medium temperature, pressure range and excitation voltage of the tested system exceed the rated use range of the transmitter; Pay attention to protect the outgoing cable of the transmitter. When the span is too large on site, it is recommended to use metal pipe for protection or overhead; The pressure transmitter is a precision measuring instrument. Do not impose impact or smash to avoid damaging the core The product is installed in a ventilated, dry and non corrosive environment, and installed in the open with protective devices to avoid direct sunlight; It is strictly prohibited to enter / leak / soak water in the product instrument, and protective devices shall be installed in the open to avoid direct sunlight;