Product description of strain type pressure transmitter:
Chip:
Adopt imported voltage sensing chip; select the chip technology, with zero, full range compensation, temperature compensation;
Diffused silicon core, high sensitivity, large output, zero point, full range compensation, temperature compensation, suitable for small range pressure transmitter;
Strain gauge core, high-strength elastic deformation pressure sensing material, equipped with temperature compensation, has the advantages of impact resistance and fatigue resistance, suitable for general range pressure transmitter;
Signal processing and control output:
4-digit digital display of current pressure value, display range: - 1999 - 9999, key adjustment and field setting of various parameters, easy to operate;
High precision stable amplification IC, 24 bit ADC sampling processing chip, DSP digital signal conditioning algorithm, multi-point line temperature calibration, voltage and current overload protection;
Two channels of PNP or NPN switching value + 4-20mA analog quantity transmission output;
Pressure preset switch point and delay switch output, switch value can be set from zero point to full degree;
The shell is provided with a node action led for easy observation;
2-way switch output with load capacity of 1.2A;
Structure:
Small structure, full seal welding structure, impact resistance, fatigue resistance, high reliability, a variety of process connection;
Process connection material, 304, diversified modes (M20, M16, M12, G1 / 4, G1 / 2, 1 / 2NPT, 1 / 4NPT, etc.);
Electrical connection: optional 4 / 5-core M12 connector, 4-core hesman connector and 4 / 5-core aviation connector;
4-core / 5-core shielded cable according to output matching standard;
Application:
Pressure measurement and control of pipeline water pressure and hydraulic equipment
Pressure measurement control of hydraulic system pipeline and hydraulic equipment
Complete with PLC and display instrument to realize the collection and input of pressure switch value
Pressure measurement in other civil / industrial automation fields
Ordering considerations
1. Product range selection:
In order to achieve the best effect of product accuracy, life, stability and other functions, the range selection of the product is calculated by referring to the following formula:
Range = x (1.2-1.5) times of the maximum system pressure;
The actual measuring pressure range of the product should be 15% - 80% of the range;
2. Product power supply and output:
Power supply range: DC 12-30vdc;
The difference of control circuit between PNP switch type and NPN switch type;
The output capacity of PNP and NPN switching value with load, driving current less than 1.2A;
Whether 4-20mA transmission output is required;
3. The user should understand the measurement medium characteristics of the product:
Medium specification, medium temperature, medium purity (whether containing impurities or particles, etc.);
4. Users should understand the installation environment and installation mode of the product:
Indoor or outdoor installation;
Ambient temperature;
Required sealing level;
Vibration range of equipment;
Installation method: thread, flange, special structure;
Whether the installation space meets the overall dimension of the product;
Precautions for use
Product power supply 24VDC (range: 9-30vdc);
It is strictly prohibited to use hard objects (such as screwdriver, finger, iron nail, etc.) to make the pressure core body under pressure measurement output;
The power and signal wires shall be correctly wired according to the specifications of the ordered products;
When the product is installed, the stressed part is "process connection hexagon wrench position", and the wrench specification corresponds to hexagon;
It is strictly prohibited that the medium temperature, pressure range and excitation voltage of the tested system exceed the rated use range of the transmitter;
Pay attention to protect the outgoing cable of the transmitter. When the span is too large on site, it is recommended to use metal pipe for protection or overhead;
The product is installed in a ventilated, dry and non corrosive environment, and installed in the open with protective devices to avoid direct sunlight;
The line connection shall be as short as possible; shielded wire shall be used; direct access to the user device causing interference or the wiring of electrical and electronic devices shall be avoided as far as possible if the micro hose is used for installation,
The housing must be grounded separately
Menu setting block diagram
Panel operating instructions
Common problem
錯誤代碼
如果因使用不當或儀表內(nèi)部出現(xiàn)故障時,儀表會顯示故障碼,并停止開關(guān)量與模擬的輸出,并閃爍顯示提示用戶及時檢修,各故障碼含義如下:
Er01---開關(guān)1輸出短路,出現(xiàn)錯誤輸出關(guān)閉且再不控制。
措施:排除短路后,重新上電
Er02---開關(guān)2輸出短路,出現(xiàn)錯誤輸出關(guān)閉且再不控制。
措施:排除短路后,重新上電
Er12---開關(guān)1/2輸出同時短路,出現(xiàn)錯誤輸出關(guān)閉且再不控制。
措施:排除短路后,重新上電。
ErEP---EEPROM數(shù)據(jù)校驗出錯,可能原因是強烈的電磁干擾或者某個器件故障。
措施:斷電后重新上電,或者進入高級用戶菜單恢復工廠設(shè)置。
ErAd---儀表內(nèi)部模數(shù)轉(zhuǎn)換出錯,可能原因是強烈的電磁干擾或者某個器件故障。
措施:排除電磁干擾,儀表殼體合理接地。
若以上故障碼出現(xiàn),經(jīng)排查檢測重新上電如仍舊無法正常工作,請與我公司聯(lián)系。
Error code
In case of improper use or internal failure of the instrument, the instrument will display the fault code, stop the switching value and analog output, and flash the display to prompt the user to repair in time. The meaning of each fault code is as follows:
Er01 --- the output of switch 1 is short circuited. In case of error, the output is closed and it is not controlled again.
Measure: after removing the short circuit, power on again
Er02 --- the output of switch 2 is short circuited. In case of error, the output will be closed and will not be controlled again.
Measure: after removing the short circuit, power on again
Er12 --- the output of 1 / 2 switch is short circuited at the same time, and the wrong output is closed without control.
Measure: after removing the short circuit, power on again.
EREP -- EEPROM data verification error, which may be caused by strong electromagnetic interference or a device failure.
Action: power on again after power failure, or enter advanced user menu to restore factory settings.
ERAD --- internal analog-to-digital conversion error of the instrument, which may be caused by strong electromagnetic interference or a device failure.
Measures: eliminate electromagnetic interference and properly ground the instrument shell.
If the above fault code appears, and the power on is still unable to work normally after troubleshooting and detection, please contact our company.